REQUEST A CONFIGURATION / PPS SERIES
Select the signal and installation you need.
PPS codes below identify inquiry families. The table defines what to review; it does not assign an unverified pressure, temperature or bandwidth rating to a supplied unit.
| Configuration request | Pressure / task | Electrical chain | Installation review | Next step |
|---|---|---|---|---|
| PPS-PRZ-FLPThin surface-pressure package | DC reference and fluctuation amplitude at the model surface | Bridge excitation, differential gain and recording headroom | Approved thickness, bond line, cable exit and installed responseKulite LQ / Endevco 8515C exact variant | Request this family ↘ |
Thin-package comparison: source facts versus requested fit
| Reference | Source geometry | Review before selection |
|---|---|---|
| Kulite LQ-062 / Endevco 8515C | Original nominal package thickness 0.76 mm | Exact suffix, range, screen, cable and installation |
| CYG512 supplier drawing | Source drawing thickness 1.2 mm | Does not establish a 0.76 mm drop-in replacement |
| CYG511 supplier drawing | Source drawing thickness 2.2 mm | Surface disturbance, mounting and signal compatibility |
| PPS-PRZ-FLP request | Dimensions selected against customer drawing | Approved drawing and measured response for the offered configuration |
01 / ENGINEERING NOTES
Define the allowed surface disturbance
A package and its adhesive can change the local surface geometry. Specify permitted protrusion, surface curvature, bond-line thickness, cable exit and environmental exposure. Nominal package thickness is only one dimension; it does not establish a flush installed sensing face.
02 / ENGINEERING NOTES
Retain the baseline with a bridge channel
A piezoresistive bridge can retain steady pressure alongside fluctuations when the chosen reference, excitation and conditioning support the task. Absolute, gauge and differential configurations need different reference arrangements. Specify the mean pressure, small fluctuation of interest, temperature drift and amplifier headroom together.
03 / ENGINEERING NOTES
Do not turn resonance into usable bandwidth
The Endevco 8515C original datasheet lists nominal resonances of 180 or 320 kHz by range and notes a small housing-cavity resonance near 70 kHz. These figures do not establish a flat measurement band. Screens, adhesive, surface mounting and the local pressure path must be included in the installed response review.
04 / ENGINEERING NOTES
Supply the model surface and recorder details
For wind-tunnel models or rotating surfaces, include curvature, attachment method, temperature, inertial loading, cable restraint and allowable aerodynamic disturbance. Rotating operation also needs a suitable signal-transfer arrangement and timing reference. No generic flatpack is automatically qualified for flight or every rotor environment.
ORIGINAL-MODEL DATA / INDEPENDENT REVIEW
Keep original specifications separate from a proposed replacement.
Facts below describe the named original models. A PPS configuration still needs its own dimensional, electrical and calibration evidence. Resonance and flat bandwidth are different quantities.
| Original model & source | Verified reference facts | Compatibility check | Review request |
|---|---|---|---|
| Kulite LQ-062 | 0.030 in / 0.76 mm nominal thin package; bridge; LQ temperature −55 to +120 °C. | LQ and LE temperature ratings differ; do not apply the LE limit to LQ. Screenless natural frequency is range-dependent; no flat DC–150 kHz guarantee. | Review this original ↘ |
| Endevco 8515C-15 / 8515C-50 | 15 or 50 psia / 1.034 or 3.447 bar absolute; 0.76 mm nominal package; 10 V bridge. | Nominal resonances 180/320 kHz do not establish a flat band; source notes a small housing-cavity resonance near 70 kHz. | Review this original ↘ |
No affiliation or universal interchangeability is implied. Pressure-port threads and electrical connector threads must be checked separately.
Source photographs and renderings identify the stated arrangements. Range, medium, output, installation and measured response must match the offered configuration. See each caption for its sensing principle.
SOURCE-DOCUMENTED HARDWARE REFERENCES
Review the package and its sensing principle.
These supplier-reference images show the indicated arrangements. Final pressure, medium, dimensional and response requirements are confirmed for the proposed configuration.


AT THE PRESSURE PORT
The installed passage changes the recorded event.
A recess adds an acoustic system.
A small cavity and connecting passage can add amplitude peaking, ringing and delay. A tapered pipe thread does not set a reproducible diaphragm depth.
Flush alignment needs dimensions.
Match the front face, sealing shoulder, gasket compression and allowed protrusion/recess. A protection layer or screen also belongs in the installed response review.
Pressure-chain questions for this configuration
Are the pictured supplier sensors 0.76 mm thick?
No. The cited CYG512 drawing is 1.2 mm and CYG511 is 2.2 mm. The 0.76 mm figure belongs to the named original-model references, not the pictured supplier units.
Does a thin sensor leave the aerodynamic surface unchanged?
No. Package protrusion, adhesive, cable routing and the local aperture can disturb the surface and alter response. Review the installed geometry and acceptable error.
Sources and scope of the comparison
- Endevco 8515C: original thin surface-mount bridge datasheet
- Kulite LQ/LE-062: original thin-package datasheet
- NIST: pressure-tubing amplitude and phase response
Original-model facts and general methods describe their named sources. They do not qualify a PPS unit or imply manufacturer affiliation.