PiezoPressureSensor.
Menu

PPS-PRZ

Piezoresistive Dynamic Pressure Sensors: DC + High Frequency

When the steady pressure baseline matters as much as its fluctuations, a piezoresistive MEMS bridge is the route to review. Specify the DC requirement and usable dynamic response separately.

Specify this configuration ↘

Technical content reviewed 16 November 2026 · PiezoPressureSensor

Piezoresistive Dynamic Pressure Sensors: DC + High Frequency: sensing and signal-path concept
Original engineering concept; configuration-specific product drawings are reviewed separately.

REQUEST A CONFIGURATION / PPS SERIES

Select the signal and installation you need.

PPS codes below identify inquiry families. The table defines what to review; it does not assign an unverified pressure, temperature or bandwidth rating to a supplied unit.

Configuration families and acceptance checks
Configuration requestPressure / taskElectrical chainInstallation reviewNext step
PPS-PRZ-062 / PPS-PRZ-190Miniature DC + dynamic bridgeAbsolute / gauge / differential reference explicitly selectedBridge mV/V, excitation, gain and output swingExact thread pitch, front/reference-side response and mediumKulite XCQ / XTL; Endevco 8510B / 8530CRequest this family ↘
PPS-PRZ-FLP / PPS-PRZ-WCTThin package / cooled assemblySurface-flow or hot-medium configuration requestBridge or conditioned output by assemblyThin sensor mounting; gas temperature vs cooled element temperatureKulite LQ / WCTV; Endevco 8515CRequest this family ↘

01 / ENGINEERING NOTES

Absolute, gauge or differential?

Define the reference before selecting a range. Absolute pressure uses a vacuum reference; gauge pressure is relative to ambient; a true differential configuration requires two pressure paths and appropriate common-mode/static ratings.

  • A two-sensor subtraction is not automatically equivalent to a rated differential sensor.
  • DC capability does not eliminate offset, thermal drift, self-heating or reference-port limitations. For differential requests, specify the dynamic response of each pressure side; a reference path may only support a slow baseline.
  • DC–150 kHz is a requested selection target, subject to range, package, protection and mounting qualification.

02 / ENGINEERING NOTES

Miniature flush installation

M5×0.5, 10-32 UNF and M8×1 are possible interface requests. Send the actual port geometry and allowed diaphragm recess. A thread designation alone cannot establish a flush fit.

  • Wind-tunnel models: record local surface geometry and allowable blockage.
  • Hydraulic or cavitation studies: check wetted materials and liquid-compatible diaphragm protection.
  • Screens, tubing and recess volumes change dynamic response and must be included in qualification. A tapered NPT interface does not locate the diaphragm at a guaranteed axial depth; flush placement needs a verified installation drawing.

03 / ENGINEERING NOTES

Bridge excitation & differential conditioning

Confirm excitation voltage, mV/V sensitivity, zero balance, output impedance, wiring and gain. A bridge output needs compatible differential conditioning; it is not an IEPE output. Balance usable voltage swing, noise and bandwidth at the required cable length.

04 / ENGINEERING NOTES

Independent replacement review

Kulite XCQ / XTL / XT-190 and Endevco 8510B / 8530C families are comparison references. Supply the complete suffix, range, reference type, temperature, connector/pinout and drawing. No blanket drop-in compatibility or fixed savings is claimed.

ORIGINAL-MODEL DATA / INDEPENDENT REVIEW

Keep original specifications separate from a proposed replacement.

Facts below describe the named original models. A PPS configuration still needs its own dimensional, electrical and calibration evidence. Resonance and flat bandwidth are different quantities.

Original reference facts checked 16 November 2026
Original model & sourceVerified reference factsCompatibility checkReview request
Kulite XCQ-062Four-arm bridge; 10 V excitation, nominal 100 mV full scale; range-dependent natural frequency.Natural frequency without screen is range-dependent (150–1000 kHz); it is not a universal flat bandwidth.Review this original ↘
Kulite XTL-190(S/L)(M)10 V bridge; 10-32 UNF or M5×0.8 variants; −55 to +175 °C / −67 to +347 °F.PDF explicitly says performance is not guaranteed in water; consult factory for medium/O-ring compatibility. M5×0.8 and M5×0.5 must be separate configurations.Review this original ↘
Endevco 8510BFour-arm gauge bridge, 10 V excitation; 10-32 UNF-2A; temperature −54 to +121 °C.Temperature compensation range is narrower than operating range. Resonance varies with range (55–900 kHz). Water/corrosive-media use requires factory review; do not treat all liquids as compatible.Review this original ↘
Endevco 8530C-100-120100 psia / 6.895 bar absolute; 10-32 UNF-2A; 10 ft / 3.048 m cable for this exact suffix.The -120 suffix indicates 10 ft cable for this listing; do not transfer specifications to every 8530C suffix.Review this original ↘

No affiliation or universal interchangeability is implied. Pressure-port threads and electrical connector threads must be checked separately.

SUPPLIER CATALOGUE REFERENCE / PIEZORESISTIVE

Pressure range and natural frequency must stay paired.

The CYG401 catalogue below describes the identified supplier model, not a released PPS specification. Output is differential millivolts. Constant-current bridge excitation does not make it a two-wire IEPE sensor.

CYG401 source catalogue, range-dependent entries
Pressure, MPabar / psi, approx.Natural frequency, kHzCatalogue rise time, μs
110 / 145.01801
220 / 290.12401
440 / 580.23200.5
660 / 870.22500.5
10100 / 1450.43200.5
20200 / 2900.84500.3
40400 / 5801.56000.3
60600 / 8702.38000.2
1001000 / 14503.810000.2

The catalogue does not define rise-time percentage or incident/reflected geometry. Natural frequency is not usable flat bandwidth. Confirm the installed response, reference pressure, medium, excitation and selected temperature option. Supplier model source.

Other sourced configurations

CYG502: source diameter 2.1 mm / 0.0827 in, absolute reference, dry clean non-corrosive gas. CYG409: cooled assembly, M20×1.5 and catalogue 0–450°C / 32–842°F under specified cooling conditions. Thin CYG511/CYG512 source drawings are 2.2/1.2 mm respectively; these are separate from a requested 0.76 mm package.

Source-model evidence and sensing principle

Source photographs and renderings identify the stated arrangements. Range, medium, output, installation and measured response must match the offered configuration. See each caption for its sensing principle.

SOURCE-DOCUMENTED HARDWARE REFERENCES

Review the package and its sensing principle.

These supplier-reference images show the indicated arrangements. Final pressure, medium, dimensional and response requirements are confirmed for the proposed configuration.

piezoresistive dynamic pressure sensor brushed steel cylinder bronze thread flush diaphragm black rear cap cyg401
Flush-diaphragm dynamic piezoresistive referenceEdited supplier photographic reference · source CYG401Source model & documentation ↗
water cooled high frequency pressure sensor steel cylinder flush threaded diaphragm blue rear cooling ports cyg409
Water-cooled piezoresistive referenceEdited supplier photographic reference · source CYG409Source model & documentation ↗
thin mems pressure sensor silver disc perforated face gold flexible ribbon cyg511
Thin-package bridge reference — 2.2 mm source drawingEdited supplier photographic reference · source CYG511Source model & documentation ↗
ultrathin mems pressure sensor dense perforated silver disc gold flex ribbon cyg512
Thin-package bridge reference — 1.2 mm source drawingEdited supplier photographic reference · source CYG512Source model & documentation ↗
miniature threaded dynamic pressure sensor flush diaphragm hex locknut slender stem cyg507
Threaded piezoresistive referenceEdited supplier photographic reference · source CYG507Source model & documentation ↗
miniature aerodynamic pressure probe slender steel cylinder perforated front plate black cable cyg502
Miniature absolute bridge-sensor referenceEdited supplier photographic reference · source CYG502Source model & documentation ↗

AT THE PRESSURE PORT

The installed passage changes the recorded event.

Concept comparison of a recessed gas passage and a diaphragm aligned to the local wall, with sealing location shown
Concept only. Actual diaphragm position, thread engagement, seal and pressure rating require the installation drawing.

A recess adds an acoustic system.

A small cavity and connecting passage can add amplitude peaking, ringing and delay. A tapered pipe thread does not set a reproducible diaphragm depth.

Flush alignment needs dimensions.

Match the front face, sealing shoulder, gasket compression and allowed protrusion/recess. A protection layer or screen also belongs in the installed response review.

Review cavity models & thermal protection ↗

Pressure-chain questions for this configuration

Does MEMS construction guarantee 150 kHz?

No. Die resonance, packaging, protective screens, range and installed response all matter. Request a usable response with a stated amplitude and phase tolerance.

Can this measure steady and changing pressure at once?

A qualified DC-coupled bridge chain can retain both. Verify offset, drift, common-mode limits and dynamic headroom at your static baseline.

Sources and scope of the comparison

Original-model facts and general methods describe their named sources. They do not qualify a PPS unit or imply manufacturer affiliation.

COMPLETE THE PRESSURE MEASUREMENT CHAIN

Specify conditioning, mounting and protection together.

Optional budget requests. Confirm the input type, response, channel count and installed compatibility. Specialist hydrophone preamplifiers, hot-zone hardline cables and cooled assemblies are quoted separately.

Review selected configuration ↘

PREPARE A REVIEWABLE BRIEF

Download the worksheets for your project.

These are blank engineering request/checklist documents. They are not released product datasheets, calibration certificates or signed quotations.

ENGINEERING RFQ / PPS-PRZ

Send this pressure configuration for review.

Include the original suffix and a private installation drawing when available. Final specifications, evidence, price and lead time are confirmed in writing.

PPS-PRZ

Pressure event & project contact
Document package requested

Optional requests for the exact offered assembly. Availability, scope and approval are confirmed during quotation.

Accessory requests for this chain

Opt in to the items you need. These are budget requests; compatibility, channel count and final price require review.

Bring the whole pressure event into focus.