REQUEST A CONFIGURATION / PPS SERIES
Select the signal and installation you need.
PPS codes below identify inquiry families. The table defines what to review; it does not assign an unverified pressure, temperature or bandwidth rating to a supplied unit.
| Configuration request | Pressure / task | Electrical chain | Installation review | Next step |
|---|---|---|---|---|
| PPS-PRZ-062 / PPS-PRZ-190Miniature DC + dynamic bridge | Absolute / gauge / differential reference explicitly selected | Bridge mV/V, excitation, gain and output swing | Exact thread pitch, front/reference-side response and mediumKulite XCQ / XTL; Endevco 8510B / 8530C | Request this family ↘ |
| PPS-PRZ-FLP / PPS-PRZ-WCTThin package / cooled assembly | Surface-flow or hot-medium configuration request | Bridge or conditioned output by assembly | Thin sensor mounting; gas temperature vs cooled element temperatureKulite LQ / WCTV; Endevco 8515C | Request this family ↘ |
01 / ENGINEERING NOTES
Absolute, gauge or differential?
Define the reference before selecting a range. Absolute pressure uses a vacuum reference; gauge pressure is relative to ambient; a true differential configuration requires two pressure paths and appropriate common-mode/static ratings.
- A two-sensor subtraction is not automatically equivalent to a rated differential sensor.
- DC capability does not eliminate offset, thermal drift, self-heating or reference-port limitations. For differential requests, specify the dynamic response of each pressure side; a reference path may only support a slow baseline.
- DC–150 kHz is a requested selection target, subject to range, package, protection and mounting qualification.
02 / ENGINEERING NOTES
Miniature flush installation
M5×0.5, 10-32 UNF and M8×1 are possible interface requests. Send the actual port geometry and allowed diaphragm recess. A thread designation alone cannot establish a flush fit.
- Wind-tunnel models: record local surface geometry and allowable blockage.
- Hydraulic or cavitation studies: check wetted materials and liquid-compatible diaphragm protection.
- Screens, tubing and recess volumes change dynamic response and must be included in qualification. A tapered NPT interface does not locate the diaphragm at a guaranteed axial depth; flush placement needs a verified installation drawing.
03 / ENGINEERING NOTES
Bridge excitation & differential conditioning
Confirm excitation voltage, mV/V sensitivity, zero balance, output impedance, wiring and gain. A bridge output needs compatible differential conditioning; it is not an IEPE output. Balance usable voltage swing, noise and bandwidth at the required cable length.
04 / ENGINEERING NOTES
Independent replacement review
Kulite XCQ / XTL / XT-190 and Endevco 8510B / 8530C families are comparison references. Supply the complete suffix, range, reference type, temperature, connector/pinout and drawing. No blanket drop-in compatibility or fixed savings is claimed.
ORIGINAL-MODEL DATA / INDEPENDENT REVIEW
Keep original specifications separate from a proposed replacement.
Facts below describe the named original models. A PPS configuration still needs its own dimensional, electrical and calibration evidence. Resonance and flat bandwidth are different quantities.
| Original model & source | Verified reference facts | Compatibility check | Review request |
|---|---|---|---|
| Kulite XCQ-062 | Four-arm bridge; 10 V excitation, nominal 100 mV full scale; range-dependent natural frequency. | Natural frequency without screen is range-dependent (150–1000 kHz); it is not a universal flat bandwidth. | Review this original ↘ |
| Kulite XTL-190(S/L)(M) | 10 V bridge; 10-32 UNF or M5×0.8 variants; −55 to +175 °C / −67 to +347 °F. | PDF explicitly says performance is not guaranteed in water; consult factory for medium/O-ring compatibility. M5×0.8 and M5×0.5 must be separate configurations. | Review this original ↘ |
| Endevco 8510B | Four-arm gauge bridge, 10 V excitation; 10-32 UNF-2A; temperature −54 to +121 °C. | Temperature compensation range is narrower than operating range. Resonance varies with range (55–900 kHz). Water/corrosive-media use requires factory review; do not treat all liquids as compatible. | Review this original ↘ |
| Endevco 8530C-100-120 | 100 psia / 6.895 bar absolute; 10-32 UNF-2A; 10 ft / 3.048 m cable for this exact suffix. | The -120 suffix indicates 10 ft cable for this listing; do not transfer specifications to every 8530C suffix. | Review this original ↘ |
No affiliation or universal interchangeability is implied. Pressure-port threads and electrical connector threads must be checked separately.
SUPPLIER CATALOGUE REFERENCE / PIEZORESISTIVE
Pressure range and natural frequency must stay paired.
The CYG401 catalogue below describes the identified supplier model, not a released PPS specification. Output is differential millivolts. Constant-current bridge excitation does not make it a two-wire IEPE sensor.
| Pressure, MPa | bar / psi, approx. | Natural frequency, kHz | Catalogue rise time, μs |
|---|---|---|---|
| 1 | 10 / 145.0 | 180 | 1 |
| 2 | 20 / 290.1 | 240 | 1 |
| 4 | 40 / 580.2 | 320 | 0.5 |
| 6 | 60 / 870.2 | 250 | 0.5 |
| 10 | 100 / 1450.4 | 320 | 0.5 |
| 20 | 200 / 2900.8 | 450 | 0.3 |
| 40 | 400 / 5801.5 | 600 | 0.3 |
| 60 | 600 / 8702.3 | 800 | 0.2 |
| 100 | 1000 / 14503.8 | 1000 | 0.2 |
The catalogue does not define rise-time percentage or incident/reflected geometry. Natural frequency is not usable flat bandwidth. Confirm the installed response, reference pressure, medium, excitation and selected temperature option. Supplier model source.
CYG502: source diameter 2.1 mm / 0.0827 in, absolute reference, dry clean non-corrosive gas. CYG409: cooled assembly, M20×1.5 and catalogue 0–450°C / 32–842°F under specified cooling conditions. Thin CYG511/CYG512 source drawings are 2.2/1.2 mm respectively; these are separate from a requested 0.76 mm package.
Source photographs and renderings identify the stated arrangements. Range, medium, output, installation and measured response must match the offered configuration. See each caption for its sensing principle.
SOURCE-DOCUMENTED HARDWARE REFERENCES
Review the package and its sensing principle.
These supplier-reference images show the indicated arrangements. Final pressure, medium, dimensional and response requirements are confirmed for the proposed configuration.






AT THE PRESSURE PORT
The installed passage changes the recorded event.
A recess adds an acoustic system.
A small cavity and connecting passage can add amplitude peaking, ringing and delay. A tapered pipe thread does not set a reproducible diaphragm depth.
Flush alignment needs dimensions.
Match the front face, sealing shoulder, gasket compression and allowed protrusion/recess. A protection layer or screen also belongs in the installed response review.
Pressure-chain questions for this configuration
Does MEMS construction guarantee 150 kHz?
No. Die resonance, packaging, protective screens, range and installed response all matter. Request a usable response with a stated amplitude and phase tolerance.
Can this measure steady and changing pressure at once?
A qualified DC-coupled bridge chain can retain both. Verify offset, drift, common-mode limits and dynamic headroom at your static baseline.
Sources and scope of the comparison
Original-model facts and general methods describe their named sources. They do not qualify a PPS unit or imply manufacturer affiliation.