IEPE & Charge-Mode Piezoelectric Pressure Transducers

Match the sensor, mounting and electronics to the pulse you need to resolve. Choose a voltage-output IEPE chain for dynamic measurements, or a charge-output configuration when temperature, sensitivity or conditioning requirements call for it.

Specify this configuration ↘

Technical content reviewed 16 November 2026 · PiezoPressureSensor

IEPE & Charge-Mode Piezoelectric Pressure Transducers: sensing and signal-path concept
Original engineering concept; configuration-specific product drawings are reviewed separately.

REQUEST A CONFIGURATION / PPS SERIES

Select the signal and installation you need.

PPS codes below identify inquiry families. The table defines what to review; it does not assign an unverified pressure, temperature or bandwidth rating to a supplied unit.

Configuration families and acceptance checks
Configuration requestPressure / taskElectrical chainInstallation reviewNext step
PPS-ICP-113 / PPS-ICP-102Flush dynamic piezoelectricDynamic excursion + static baseline, psi / bar / MPaIEPE voltage; current, bias and headroom by configurationClamp/ground isolation, installed response and seal geometryPCB Piezotronics 113B / 102BRequest this family ↘
PPS-ICP-106 / PPS-ICP-105Low-level pulsation / miniatureLow-amplitude signal or miniature-port requirementIEPE sensitivity and noise floor to be selectedDiaphragm size, noise, pulse spectrum and port constraintsOriginal 106B / 105C suffix requiredRequest this family ↘
PPS-CHG-HTCharge output for thermal exposurePressure range and duration supplied in the RFQpC/bar or pC/psi; external charge amplifierCrystal, insulation, cable hot zone and time constantOriginal charge model + temperature dutyRequest this family ↘
PPS-CHG-H2CYLCylinder pressure / hydrogen requestAbsolute baseline, cyclic peak and overload separatelyCharge sensitivity and complete conditioning chainHydrogen/material review, front seal and thermal responseKistler 6052C full variant for reviewRequest this family ↘
PPS-BLT-BALHigh-pressure chamber requestApplication envelope up to 700 MPa requested; not a released ratingCharge or IEPE selected against signal headroomRange vs proof/burst, pulse fatigue, port and protective assemblyKistler 6215 / original ballistic modelRequest this family ↘

01 / ENGINEERING NOTES

Two outputs. Two different measurement chains.

IEPE sensors contain electronics and need a compatible constant-current supply with adequate compliance voltage. Cable capacitance and required voltage slew can exhaust available drive current even when small-signal bandwidth looks sufficient. Charge-mode sensors generate a charge signal and need a charge amplifier or suitable converter. Connecting raw charge output to an ordinary voltage input does not create a calibrated measurement.

  • PPS-ICP: request mV/psi or mV/bar sensitivity, current, bias voltage and maximum voltage swing.
  • PPS-CHG: request pC/bar sensitivity, insulation resistance, charge range and amplifier time constant.
  • Both routes: define peak pressure, static baseline, pulse duration, repetition and required amplitude/phase tolerance.

02 / ENGINEERING NOTES

Water hammer, hydraulic spikes & compressor pulsation

A fast pressure transient can be distorted by a remote port, narrow passage, process filter or insufficient acquisition bandwidth. Review the installed transfer function before assigning the whole error to the sensor.

  • Flush diaphragm installation: supply the port drawing, seal arrangement, torque limits and wetted materials.
  • Acceleration compensation can reduce sensitivity to pipe motion; residual cross-sensitivity still needs verification.
  • Combustion: separate mean pressure, dynamic excursion, gas temperature and short-duration thermal exposure.

03 / ENGINEERING NOTES

High pressure is a separate qualification

The requested 100–700 MPa envelope is a configuration review target. It is not a rating of every PPS family. Measurement range, proof pressure, burst pressure, fatigue and repeated pulse behavior require distinct evidence. 100,000 psi is approximately 689.5 MPa.

04 / ENGINEERING NOTES

What a replacement review needs

Specify pulse duration and permitted signal droop as well as rise time: a short discharge time constant can distort a long plateau. Submit the complete original model suffix and dimensional drawing. PCB 111A / 112A / 113B / 102B and Kistler 601C / 603C / 211B references can start an independent comparison; they do not establish interchangeability.

  • Thread, diaphragm position, sealing shoulder, cable and connector.
  • Sensitivity, polarity, range, temperature, installed frequency response and calibration.
  • Supply/conditioning, insulation and environment-specific material compatibility.

ORIGINAL-MODEL DATA / INDEPENDENT REVIEW

Keep original specifications separate from a proposed replacement.

Facts below describe the named original models. A PPS configuration still needs its own dimensional, electrical and calibration evidence. Resonance and flat bandwidth are different quantities.

Original reference facts checked 16 November 2026
Original model & sourceVerified reference factsCompatibility checkReview request
PCB Piezotronics 113B225,000 psi / 344.7 bar; 1 mV/psi; resonance ≥500 kHz; rise time ≤1 μs.The range is for ±5 V output. Resonance is not flat bandwidth. Mounting uses a separate floating clamp nut; electrical 10-32 is not a pressure-port thread.Review this original ↘
PCB Piezotronics 102B5,000 psi / 344.7 bar; 1 mV/psi; 3/8-24 mount; 10-32 electrical connector.Do not conflate mechanical 3/8-24 mounting with electrical 10-32 connector. M/S suffix variants require their own verification.Review this original ↘
Kistler 601CPiezoStar PE/IEPE family; series pressure to 250 bar / 3,626 psi, variant-specific.Pressure/output/temperature must be confirmed by complete variant; no universal 601C suffix compatibility is established.Review this original ↘
Kistler 603CQuartz PE/IEPE family; series pressure to 1,000 bar / 14,504 psi, variant-specific.Official JP route was opened successfully; US long-form route returned a tool access error. Full variant and mount remain necessary.Review this original ↘

No affiliation or universal interchangeability is implied. Pressure-port threads and electrical connector threads must be checked separately.

Source-model evidence and sensing principle

Source photographs and renderings identify the stated arrangements. Range, medium, output, installation and measured response must match the offered configuration. See each caption for its sensing principle.

SOURCE-DOCUMENTED HARDWARE REFERENCES

Review the package and its sensing principle.

These supplier-reference images show the indicated arrangements. Final pressure, medium, dimensional and response requirements are confirmed for the proposed configuration.

Charge-output piezoelectric pressure-sensor reference — supplier rendering.
Charge-output reference — supplier temperature limit +150°CEdited supplier rendering · source KD2004Source model & documentation ↗
IEPE dynamic pressure-sensor configuration reference.
IEPE dynamic pressure reference — source 0–30 MPaEdited supplier photographic reference · source Y1001ESource model & documentation ↗

AT THE PRESSURE PORT

The installed passage changes the recorded event.

Concept comparison of a recessed gas passage and a diaphragm aligned to the local wall, with sealing location shown
Concept only. Actual diaphragm position, thread engagement, seal and pressure rating require the installation drawing.

A recess adds an acoustic system.

A small cavity and connecting passage can add amplitude peaking, ringing and delay. A tapered pipe thread does not set a reproducible diaphragm depth.

Flush alignment needs dimensions.

Match the front face, sealing shoulder, gasket compression and allowed protrusion/recess. A protection layer or screen also belongs in the installed response review.

Review cavity models & thermal protection ↗

Pressure-chain questions for this configuration

Can a piezoelectric pressure sensor measure static pressure?

It cannot retain a truly static signal indefinitely. A sufficiently long discharge time constant can support limited quasi-static measurements, with droop and measurement duration evaluated together.

Does 500 kHz resonance mean 500 kHz usable bandwidth?

No. The flat measurement region is lower and depends on the specified amplitude/phase error, mounting, electronics and cable. Request the calibrated installed response.

Sources and scope of the comparison

Original-model facts and general methods describe their named sources. They do not qualify a PPS unit or imply manufacturer affiliation.

COMPLETE THE PRESSURE MEASUREMENT CHAIN

Specify conditioning, mounting and protection together.

Optional budget requests. Confirm the input type, response, channel count and installed compatibility. Specialist hydrophone preamplifiers, hot-zone hardline cables and cooled assemblies are quoted separately.

Review selected configuration ↘

PREPARE A REVIEWABLE BRIEF

Download the worksheets for your project.

These are blank engineering request/checklist documents. They are not released product datasheets, calibration certificates or signed quotations.

ENGINEERING RFQ / PPS-ICP / PPS-CHG

Send this pressure configuration for review.

Include the original suffix and a private installation drawing when available. Final specifications, evidence, price and lead time are confirmed in writing.

PPS-ICP / PPS-CHG

Pressure event & project contact
Document package requested

Optional requests for the exact offered assembly. Availability, scope and approval are confirmed during quotation.

Accessory requests for this chain

Opt in to the items you need. These are budget requests; compatibility, channel count and final price require review.

Bring the whole pressure event into focus.

Discuss your application ↗