PiezoPressureSensor.
Menu

APPLICATION / AERODYNAMIC SURFACE PRESSURE

Wind-Tunnel & eVTOL Surface-Pressure Measurement

Retain mean surface pressure and unsteady fluctuations with miniature bridge channels selected for the model geometry. Installed aperture, surface disturbance and phase response matter alongside the sensing element.

Specify this configuration ↘

Technical content reviewed 16 November 2026 · PiezoPressureSensor

Wind-Tunnel & eVTOL Surface-Pressure Measurement: sensing and signal-path concept
Original engineering concept; configuration-specific product drawings are reviewed separately.

REQUEST A CONFIGURATION / PPS SERIES

Select the signal and installation you need.

PPS codes below identify inquiry families. The table defines what to review; it does not assign an unverified pressure, temperature or bandwidth rating to a supplied unit.

Configuration families and acceptance checks
Configuration requestPressure / taskElectrical chainInstallation reviewNext step
PPS-PRZ-062 / PPS-PRZ-190Miniature DC + dynamic bridgeAbsolute / gauge / differential reference explicitly selectedBridge mV/V, excitation, gain and output swingExact thread pitch, front/reference-side response and mediumKulite XCQ / XTL; Endevco 8510B / 8530CRequest this family ↘
PPS-PRZ-FLPThin surface-pressure packageDC reference and fluctuation amplitude at the model surfaceBridge excitation, differential gain and recording headroomApproved thickness, bond line, cable exit and installed responseKulite LQ / Endevco 8515C exact variantRequest this family ↘

Aerodynamic pressure channel plan

Aerodynamic pressure channel plan
MeasurementCandidate routeInstallation / acquisition check
Model-surface mean + fluctuationPPS-PRZ-062 / PPS-PRZ-190 miniature bridgeReference routing, screen, port volume and channel phase
Thin bonded surface packagePPS-PRZ-FLP reviewThickness plus adhesive, curvature, cable exit and local disturbance
Rotating surface-pressure recordEnvironment-qualified bridge assemblyRetention, inertial loading, signal transfer and synchronized timing
Far-field acoustic recordSeparate acoustic instrumentationSurface pressure alone does not establish far-field sound

01 / ENGINEERING NOTES

State surface pressure or acoustic pressure explicitly

A wall-pressure sensor samples the local surface field. A far-field microphone measures a different field with different calibration and placement requirements. NASA’s eVTOL acoustic source-separation paper uses synchronized aircraft position, rotor speed and acoustic data. Surface-pressure spectra alone do not establish radiated sound or aircraft acoustic certification.

02 / ENGINEERING NOTES

Match aperture and pressure reference to the model

Absolute, gauge and differential configurations have different reference paths. Small apertures help limit spatial averaging, but screens, internal cavities and tubing can alter amplitude and phase. Supply the model drawing, local curvature, reference routing and the required fluctuation level above the mean.

03 / ENGINEERING NOTES

Thin packaging still needs installed acceptance

The complete surface profile includes the sensor, adhesive and cable. Review allowable protrusion and attachment rather than assuming a nominal 0.76 mm source package is aerodynamically invisible. The pictured CYG512 supplier reference has a 1.2 mm source drawing, not the original LQ/8515C thickness.

04 / ENGINEERING NOTES

Rotating measurements require more than a small sensor

For a rotating surface, state thermal and inertial loading, cable restraint, signal-transfer method and timing reference. Bridge excitation and differential amplification must work through the complete connection. Ask for installation and environmental evidence for the exact assembly; a wind-tunnel configuration is not automatically flight-qualified.

ORIGINAL-MODEL DATA / INDEPENDENT REVIEW

Keep original specifications separate from a proposed replacement.

Facts below describe the named original models. A PPS configuration still needs its own dimensional, electrical and calibration evidence. Resonance and flat bandwidth are different quantities.

Original reference facts checked 16 November 2026
Original model & sourceVerified reference factsCompatibility checkReview request
Kulite XCQ-062Four-arm bridge; 10 V excitation, nominal 100 mV full scale; range-dependent natural frequency.Natural frequency without screen is range-dependent (150–1000 kHz); it is not a universal flat bandwidth.Review this original ↘
Kulite LQ-0620.030 in / 0.76 mm nominal thin package; bridge; LQ temperature −55 to +120 °C.LQ and LE temperature ratings differ; do not apply the LE limit to LQ. Screenless natural frequency is range-dependent; no flat DC–150 kHz guarantee.Review this original ↘
Endevco 8515C-15 / 8515C-5015 or 50 psia / 1.034 or 3.447 bar absolute; 0.76 mm nominal package; 10 V bridge.Nominal resonances 180/320 kHz do not establish a flat band; source notes a small housing-cavity resonance near 70 kHz.Review this original ↘

No affiliation or universal interchangeability is implied. Pressure-port threads and electrical connector threads must be checked separately.

Source-model evidence and sensing principle

Source photographs and renderings identify the stated arrangements. Range, medium, output, installation and measured response must match the offered configuration. See each caption for its sensing principle.

SOURCE-DOCUMENTED HARDWARE REFERENCES

Review the package and its sensing principle.

These supplier-reference images show the indicated arrangements. Final pressure, medium, dimensional and response requirements are confirmed for the proposed configuration.

ultrathin mems pressure sensor dense perforated silver disc gold flex ribbon cyg512
Thin-package bridge reference — 1.2 mm source drawingEdited supplier photographic reference · source CYG512Source model & documentation ↗
miniature aerodynamic pressure probe slender steel cylinder perforated front plate black cable cyg502
Miniature absolute bridge-sensor referenceEdited supplier photographic reference · source CYG502Source model & documentation ↗

Pressure-chain questions for this configuration

Can surface-pressure measurements alone establish far-field noise?

No. Surface pressure and radiated acoustic pressure are different measurands. A far-field acoustic result needs its own instrumentation, placement and analysis.

Does miniature packaging imply flight qualification?

No. The exact installed assembly needs the environmental, attachment, electrical and acceptance evidence required by the intended use.

Sources and scope of the comparison

Original-model facts and general methods describe their named sources. They do not qualify a PPS unit or imply manufacturer affiliation.

COMPLETE THE PRESSURE MEASUREMENT CHAIN

Specify conditioning, mounting and protection together.

Optional budget requests. Confirm the input type, response, channel count and installed compatibility. Specialist hydrophone preamplifiers, hot-zone hardline cables and cooled assemblies are quoted separately.

Review selected configuration ↘

PREPARE A REVIEWABLE BRIEF

Download the worksheets for your project.

These are blank engineering request/checklist documents. They are not released product datasheets, calibration certificates or signed quotations.

ENGINEERING RFQ / APPLICATION / AERODYNAMIC SURFACE PRESSURE

Send this pressure configuration for review.

Include the original suffix and a private installation drawing when available. Final specifications, evidence, price and lead time are confirmed in writing.

PPS aerodynamic pressure channel review

Pressure event & project contact
Document package requested

Optional requests for the exact offered assembly. Availability, scope and approval are confirmed during quotation.

Accessory requests for this chain

Opt in to the items you need. These are budget requests; compatibility, channel count and final price require review.

Bring the whole pressure event into focus.

Discuss your application ↗